3 Tutorial 4 — Using Measurement Tools in an Inspection Advanced Tool Tutorials On the properties page, observe that the Nominal Distance is set to the output value of the above Pin to Pin Distance, the Tolerance+/- is set to be the value that is 5% of the Nominal Distance. 58. Highlight Left Pin to Center Distance tolerance (left pane). 59. In the Properties pane, set the following Left Pin to Center Distance tolerance parameters: – Input Datum — Left to Center.Pt-Pt Distance – With Tolerance — 5% Nominal 60. Minimize the Step Tree Editor. 61. Click .
On the properties page, observe that the Nominal Distance is set to the output value of the above Left Pin to Center Distance, the Tolerance+/- is set to be the value that is 5% of the Nominal Distance. 62. Highlight Right to Center and click . 63. In the Properties (Figure 3–29), set Graphics Level to Show Graphics. 64. To select the reference for Point1, click in the area to the right of the blue arrow (Figure 3–29), and click on the three dots, which displays the Select Reference window, as shown in Figure 3–30. FIGURE 3–29. Select Reference Button Getting Started with Visionscape GigE Cameras 3-39