hengstler · 2 стр.

Hengstler 886 - 887 Adding Preset Counter Datasheet (EN)

Оригинальное название: Hengstler 886 - 887 Adding Preset Counter Datasheet

Читать онлайн

Похожие инструкции

Текст документа

email: sales@impulseautomation.co.uk web: www.impulseautomation.co.uk Adding Preset Counters for Front Panel Mounting Type 886/887 Preset value continuously visible Manual or electric reset 3 or 5-digit indication Various front panel sizes available TECHNICAL DATA Display 3 or 5-digit indication of count and preset value, depending on version Digit height 4 mm Supply voltage V op see ordering code table, tolerance ± 10 % 230 VAC + 6–10 % Power consumption counter: DC version 2.5 W, AC version 2.75 VA reset solenoid: DC version 12 W, AC version 16 VA Residual ripple 48 % Operating temperature – 10 … + 50 °C Storage temperature – 40 …

+ 85 °C Electrical connection AMP connector, 0.8 x 2.8 mm Mounting screw or clamping spring attachment, see "Order information" Mounting position roller axis horizontal Protection class front IP 30; connections IP 00; for higher degree of (EN 60529) protection we recommend a protective case with clear cover (see "Accessories") General design EN 61010-1, EN 50178 Protection according to class II Contamination level 2 Over voltage category II Duty cycle at 25 °C Counter 100 %, reset solenoid: DC version 20 %, max. 2 minutes, AC versions 10 %, max. 1 minute at 50 °C Counter 50 %, max. 10 minutes Maintenance-free operation Counter:

2 x 10 8 , reset solenoid 1.5 x 10 6 pulses Approvals Count input adding Min. pulse length DC version 20 ms, AC version 50 ms Max. counting frequency DC version 25 Hz, AC version 10 Hz Pulse duty factor 1:1 Reset – manual with button external by electrical signal (versions with reset solenoid only), min. pulse length 200 ms (max. see duty cycle); Reset frequency DC version max. 1 per 2 s Pulse duty factor DC version 1:5, AC version 1:10 Signal output Signal duration from when preset has been reached until reset Contact type changeover contact, floating Switching voltage max. 220 VAC Switching current max.

20 VA/1 A, non-inductive Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC074 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 24-10-19 1 of 2

Стр. 1

Technical data Type 886/887 CONNECTION DIAGRAM DIMENSIONS Front panel 60 mm x 75 mm Front panel 55 mm x 53 mm ORDER INFORMATION 3 digits 5 digits Counters for screw attachment Front panel 60 mm x 75 mm Voltage button reset el. reset button reset el. reset 24 VDC 0 887 264 0 887 214 0 886 264 0 886 214 115 VAC 0 887 289 0 886 289 0 886 239 230 VAC 0 887 290 0 887 240 0 886 290 0 886 240 COUNTERS FOR SPRING ATTACHMENT Front panel 55 mm x 53 mm stigid 5 stigid 3 Voltage button reset el. reset button reset el. reset 24 VDC 0 887 464 0 887 414 0 886 464 0 886 414 0 4 4 6 8 8 0 0 9 4 6 8 8 0 C A V 0 3 2 Inquire for other voltages For key reset add ordering code + SR, e.g.

0 887 264 SR Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Doc No: TTCC074 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 24-10-19 2 of 2

Стр. 2