email: sales@impulseautomation.co.uk web: www.impulseautomation.co.uk Time Counter with DIN Dimensions for AC and DC Operation Type 891 I Low-cost I DIN dimensions 24 x 48 mm, 48 x 48 mm or 72 x 72 mm I Highly legible display I Simple installation I No reset TECHNICAL DATA Display 7-digit, 0 ... 99999.99 h Digit height 5 mm, visual Supply voltage V op acc. to order information + 10 % (230 VAC + 15 %) Power consumption 0.7 VA or max 750 mW on DC Operating temperature - 10 ... + 50 °C Storage temperature - 20 ... + 70 °C El. connection screw terminals for cables of max.

2.5 mm 2 and AMP connector 6.3 x 0.8 mm Mounting with clamping frame (Ordering code 2 891 016) Mounting position roller axis horizontal Protection class (IEC 144) front IP 66; screw terminals IP 20, AMP connectors IP 00 Vibrostability 30 m/s 2 (10 ... 500 Hz) acc. to IEC 068-2-6 Shock stability 800 m/s 2 (6 ms) acc. to IEC 068-2-27 General design acc. to DIN VDE, part 1, protection according to class II, Contamination level 2; Overvoltage category II Weight approx. 50 g Approvals UL: E 130453 (M), CSA (only AC version) Reset none CONNECTION DIAGRAM VDC + 0V + VAC M M Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.

The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. DC AC Doc No: TTCC077 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 08-11-19 1 of 4

Стр. 1

Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. Technical data Type 891 DIMENSIONS (62,5 bei DC) Counter Seal: Ordering code 2 405 231 (0.5 mm) Installation frame Dimensions in mm ORDER INFORMATION Voltage Power 50 Hz 60 Hz Counter consumption Ordering code Ordering code 24 VAC 0.1 VA 0 891 201 0 891 202 115 VAC 0.6 VA 0 891 203 0 891 204 230 VAC 0.7 VA 0 891 211 0 891 206 100 VAC 0.,3 VA 0 891 213 0 891 214 200 VAC 0.7 VA 0 891 215 0 891 216 Voltage Max.

power consumption Ordering code external resistor 12… 36 VDC 350 mW 0 891 331 40… 60 VDC 620 mW 0 891 331 + 6,8 kΩ/1 W 80…125 VDC 1100 mW 0 891 331 + 15 kΩ/1 W Installation frame Frame Seal Size Installation cutout Ordering code Ordering code A 54 x 29 mm 50 x 25 mm 2 405 218 2 405 232 B 48 x 48 mm 45 x 45 mm 2 405 219 2 405 233 C 52 x 52 mm  50 mm 2 405 220 2 405 234 D 72 x 72 mm 68 x 68 mm 1 405 672 2 405 235 E  73 mm  50 mm 2 405 223 2 405 237 F  58 mm  50 mm 2 405 224 2 405 236 Voltage Max. power consumption Ordering code external resistor 12… 36 VDC 350 mW 0 891 331 40…

60 VDC 620 mW 0 891 331 + 6,8 kΩ/1 W 80…125 VDC 1100 mW 0 891 331 + 15 kΩ/1 W Frame Seal Size Installation cutout Ordering code Ordering code A 54 x 29 mm 50 x 25 mm 2 405 218 2 405 232 B 48 x 48 mm 45 x 45 mm 2 405 219 2 405 233 C 52 x 52 mm  50 mm 2 405 220 2 405 234 D 72 x 72 mm 68 x 68 mm 1 405 672 2 405 235 E  73 mm  50 mm 2 405 223 2 405 237 F  58 mm  50 mm 2 405 224 2 405 236 Doc No: TTCC077 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 08-11-19 2 of 4

Стр. 2

tico 007 Time Counter for Surface Mounting, Suitable for AC and DC Operation Type 891 I Low-cost I DIN rail attachment I Highly legible display I Simple installation I No reset TECHNICAL DATA Display 7-digit, 0 ... 99999.99 h Digit height 5 mm, visual Supply voltage V op acc. to order information + 10 % (230 VAC + 15 %) Power consumption 0.7 VA on AC - 750 mW on DC Operating temperature - 10 ... + 50 °C Storage temperature - 20 ... + 70 °C El. connection screw terminals for cables of max.

2.5 mm 2 and AMP connector 6.3 x 0.8 mm Mounting with screws or on DIN rail Mounting position roller axis horizontal Protection class (IEC 144) front IP 66; screw terminals IP 20, AMP connectors IP 00 Vibrostability 30 m/s 2 (10 ... 500 Hz) acc. to IEC 068-2-6 Shock stability 800 m/s 2 (6 ms) acc. to IEC 068-2-27 General design acc. to DIN VDE, part 1, protection according to class II, Contamination level 2; Overvoltage category II Weight approx. 50 g Reset none CONNECTION DIAGRAM VDC + 0V VAC M M Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.

The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. DC AC Doc No: TTCC077 Rev: 001 Impulse Automation Limited United Kingdom Company Registration 665193 Page 08-11-19 3 of 4

Стр. 3

Technical data Type 891 DIMENSIONS Counter Cover can be screw-mounted Dimensions in mm ORDER INFORMATION Counter Voltage Power Voltage Ordeiring code consumption tolerance 24 V 50 Hz 0.1 VA ± 10 % 0 891 501 24 V 60 Hz 0.1 VA ± 10 % 0 891 502 115 V 50 Hz 0.6 VA ± 10 % 0 891 503 115 V 60 Hz 0.6 VA ± 10 % 0 891 504 230 V 50 Hz 0.7 VA ± 15 % 0 891 511 12- 36 V DC max. 550 mW ± 10 % 0 891 531 40- 60 V DC max. 50 mW ± 10 % 0 891 532 80-125 V DC 750 mW ± 10 % 0 891 533 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions.