Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk BI17 Series Bistable Linear Solenoid Push & Pull Type Order specifications Linear solenoid Design type Coil terminals Flying leads (10 cm standard length) Nominal voltage (standard voltage) 1) Perm. duty cycle under air cooled conditions (LK) 1) Other voltages are available on request up to 60 V DC Weight: Complete solenoid: appr. 46 g Armature: appr. 12 g Standard: Voltage: 24 V DC Flying leads: 10 cm Insulation class: E (max. permissible temperature = 120 ° C) 24 V DC 25% ED BI 17-F Document BSS017/12 Revision 00 2 10 %ED 8 Force vs.
Stroke diagram F = f (s) F/N 6 5 spring force permanent force 4 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 3 25 2 stroke s = 0 corresponds to armature in fully home position Force vs. stroke characteristics measured without return spring 1 0 1 2 3 4 s/mm Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
BI 17 – F – 24 V DC 25 % ED BI 17 F 24 25 % ED 25 % Perm. duty cycle (ED) 9,5 W Nominal coil power Pn 22 ms Actuation time (ED) 11 ms Drop-out time
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk BI17 Series Bistable Linear Solenoid Push & Pull Type 30 16,5 64 10 +1 M3 Ш12 Ш7 2 Ш6 8 0,4 10 ± 0,3 4 M2,5 5 12 3,5 8 Dimensions given with armature in fully home position Direction of stroke Document BSS017/22 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described. 17