Kuhnke · 2 стр.
Руководство по эксплуатации Kuhnke HM1 Linear Solenoid (EN)
Оригинальное название: Kuhnke HM1 Linear Solenoid Datasheet
Похожие инструкции
Текст документа
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk HM1 Series Linear Solenoid Push or Pull Type 1) Other DC voltages are available on request . Weight: Complete solenoid: appr. 32 g Armature: appr. 8 g Standard: Voltage: 24 V DC Flying leads: 10 cm Insulation class: E (max. permissible temperature = 120 ° C) HM 1 57 - F 24 V DC 100% ED 2) If solenoid is mounted directly onto a flat metal surface of at least 30 cm 2 , the duty cycle can be extended up to 1.3 x nominal rating 3) Stroke 5 mm 5 6 %ED Document LNSHM1/12 Revision 00 2 3 F/N 2 1 5 Force vs.
Stroke diagram F = f (s) 0,5 0,2 0,3 15 Force measured when operating in horizontal position, at 90 % rated voltage and with winding at operating temperature 25 0,06 0,08 0,1 100 70 45 stroke s = 0 corresponds to armature in fully home position 0 1 2 3 4 5 7 6 s/mm Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
HM 1 07 – F – 24 V DC 100 % ED Ord er specifications HM Line ar solenoid 1 Size s Desi gn type 07 Pull type solenoid 57 Thrust type solenoid Coil terminals F Flying leads (10 cm standard length) 24 No minal voltage (standard voltage)1) 100 % ED Per m. duty cycle under air cooled conditions (LK) 100 70 45 25 15 5 % Perm. duty cycle (ED)2) 2,8 4,3 6,5 10 18 52 W Nominal coil power Pn 34 8 ms Actuation time (ED)3)
Email: sales@impulseautomation.co.uk Website: www.impulseautomation.co.uk HM1 Series Linear Solenoid Push or Pull Type M3 0,5 Ш6 Document LNSHM1/22 Revision 00 2 Impulse Automation Limited United Kingdom Company Registration 665193 Information shown in these data sheets are for guidance purposes only, no liability is accepted for any errors or omissions. The designer or user is solely responsible for the safe and proper use of these parts, assemblies or equipment described.
Series HM 107 pull type solenoid 8 2 Ø5,2 11,5 15 10 38 2 Dimensions given with armature in fully home position 16 9 3,5 –––––––> Direction of stroke 48,2 Series HM 157 thrust type solenoid M3 ≤0,5 Ø5,2 M2 11,5 Ø6 15 10 38 16,5±0,3 Dimensions given with armature in fully home position 16 9 5+1 –––––––> Direction of stroke 55 9 16 Ø6 15 1 38 9