3. New functions of output instructions: API 57 Operands: S 1 : Pulse output frequency S 2 : Number of output pulses D : Pulse output device (please use transistor output module) Explanations: 1. S 1 designates the pulse output frequency. With M1133 ~ M1135 and D1133, Y0 of SA/SX series MPU is able to output pulses at 50kHz. SV/EH2/EH3/SV2 series MPU of V1.4 and later versions use M1190 ~ M1191, and Y0 and Y2 are able to output 0.01 ~ 500Hz. Range of output frequency for all series: Note: Only 24SV2 supports Y10 and Y12. 2. S 2 designates the number of output pulses. The 16-bit instruction can designate 1 ~ 32,767 pulses and the 32-bit instruction can designate 1 ~ 2,147,483,647 pulses.

Number of continuous pulses for all series: 3. For EH/EH2/SV/EH3/SV2 series MPU, when the number of output pulses is set to 0, there will be continuous pulse output with no limitation on the number of pulses. For ES/EX/SS/SA/SX/SC series MPU, you have to make Mnemonic Operands Function D PLSY Pulse Y Output Type OP Bit Devices Word Devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F PLSY: 7 steps DPLSY: 13 steps S 1 * * * * * * * * * * * S 2 * * * * * * * * * * * D * PULSE 16-bit 32-bit SS S A SX SC EH SV EH3 SV2 EH3 EH3 ES EX ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV SV2 SV2 EH2/SV/EH3/SV2 MPU ES/EX/SS SA/SX SC EH (Note) Frequency range 0~10kHz Y0: 0~32kHz Y1: 0~10kHz Y0:

0~30kHz Y1: 0~30kHz Y10: 77~100kHz Y11: 77~100kHz Y0: 1~200kHz Y2: 1~200kHz Y0: 0~200kHz Y2: 0~200kHz Y4: 0~200kHz Y6: 0~200kHz Y10: 0~10kHz Y12: 0~10kHz MPU ES/EX/SS/SA/SX/SC SC EH/EH2/SV/EH3/SV2 How to designate continuous pulses M1010 (Y0) On M1023 (Y1) On M1010 (Y0) On M1023 (Y1) On The number of output pulses designated for Y10 and Y11 is set to K0. The number of output pulses designated for Y0, Y2, Y4, Y6, Y10, and Y12 is set to K0.