When using an encoder cable (FR-JCBL, FR-V5CBL, etc.) dedicated to the conventional motor, the cables need to be treated as the terminal block of the FR-A8AP is an insertion type. Cut the crimp terminal of the encoder cable and strip its sheath to make its cable wires loose. Also, treat the shielding wires of the shielded twisted pair cable to ensure that they 1 do not contact conductive areas. Twist the stripped end of wires to prevent them from fraying. In addition, do not solder it. 2 Cable stripping size 3 5 mm 4 Information on crimp terminals Commercially available products (as of October 2020) Phoenix Contact Co., Ltd. 5 6 NICHIFU Co., Ltd.
7 When using a blade terminal (without insulation sleeve), take caution that the twisted wires do not come out. 8 9 Connection terminal compatibility table 10 91 2. INSTALLATION AND WIRING 2.8 Connection to a motor with encoder (Vector control) NOTE Terminal screw size Wire gauge (mm2) Ferrule part No. Crimping tool model No. With insulation sleeve Without insulation sleeve M2 0.3 AI 0,34-6TQ A 0,34-7 CRIMPFOX 6 0.5 AI 0,5-6WH A 0,5-6 Terminal screw size Wire gauge (mm2) Blade terminal part No. Insulation cap part No. Crimping tool model No.
M2 0.3 to 0.75 BT 0.75-7 VC 0.75 NH 69 Motor SF-V5RU, SF-THY SF-JR/HR/JRCA/HRCA (with encoder) Encoder cable FR-V7CBL FR-JCBL FR-A8AP terminal PA1 PA PA PA2 Do not connect anything to this. PAR PB1 PB PB PB2 Do not connect anything to this. PBR PZ1 PZ PZ PZ2 Do not connect anything to this. PZR PG PG 5E SD SD AG2