Текст документа
Delta Standard Compact Drive - MS300 Series User Manual (High Speed Models) Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center 18 Xinglong Road, Taoyuan District, Taoyuan City 33068, Taiwan (R.O.C.) TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Asia Delta Electronics (Jiangsu) Ltd. Wujiang Plant 3 1688 Jiangxing East Road, Wujiang Economic Development Zone Wujiang City, Jiang Su Province, P.R.C. 215200 TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290 Delta Greentech (China) Co., Ltd. 238 Min-Xia Road, Pudong District, ShangHai, P.R.C. 201209 TEL: 86-21-58635678 / FAX: 86-21-58630003 Delta Electronics (Japan), Inc.
Tokyo Office 2-1-14 Minato-ku Shibadaimon, Tokyo 105-0012, Japan TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211 Delta Electronics (Korea), Inc. 1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Seoul, Korea, 153-704 TEL: 82-2-515-5303 / FAX: 82-2-515-5302 Delta Standard Compact Drive MS300 Series User Manual Delta Electronics Int’l (S) Pte Ltd. 4 Kaki Bukit Ave 1, #05-05, Singapore 417939 TEL: 65-6747-5155 / FAX: 65-6744-9228 Delta Electronics (India) Pvt. Ltd. Plot No 43 Sector 35, HSIIDC Gurgaon, PIN 122001, Haryana, India TEL : 91-124-4874900 / FAX : 91-124-4874945 (High Speed Models) Americas Delta Products Corporation (USA) Raleigh Office P.O.
Box 12173,5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: 1-919-767-3800 / FAX: 1-919-767-8080 Delta Greentech (Brasil) S.A. Sao Paulo Office Rua Itapeva, 26 - 3° andar Edificio Itapeva One-Bela Vista 01332-000-Sгo Paulo-SP-Brazil TEL: 55 11 3568-3855 / FAX: 55 11 3568-3865 Europe Delta Electronics (Netherlands) B.V. Eindhoven Office De Witbogt 20, 5652 AG Eindhoven, The Netherlands TEL: +31 (0)40-8003800 / FAX: +31 (0)40-8003898 5014063800-E0MS-20170 3 *We reserve the right to change the information in this user manual without prior notice. www.deltaww.com
PLEASE READ PRIOR TO INSTALLATION FOR SAFETY. For a detailed explanation of the product specifications, the cover or the safety shields will be disassembled on some pictures or graphics. When the product is put to operation, please install the top cover and safety shield and ensure correct wiring. Refer to the manual to ensure safe operation. The figures in this instruction are for reference only, they may be slightly different from your actual drive, but it will not affect your customer rights. The content of this manual may be revised without prior notice.
Please consult our distributors or download the latest version at http://www.deltaww.com/services/DownloadCenter2.aspx?secID=8&pid=2&tid=0&CID=06&itemID=060101&typeID =1&downloadID=&title=&dataType=&check=0&hl=en-US I AC input power must be disconnected before any wiring to the AC motor drive is made. Even if the power has been turned off, a charge may still remain in the DC-link capacitors with hazardous voltages before the POWER LED is OFF. Please do not touch the internal circuit and components. There are highly sensitive MOS components on the printed circuit boards. These components are especially sensitive to static electricity.
Please do not touch these components or the circuit boards before taking anti-static measures. Never reassemble internal components or wiring. Ground the AC motor drive using the ground terminal. The grounding method must comply with the laws of the country where the AC motor drive is to be installed. DO NOT install the AC motor drive in a place subjected to high temperature, direct sunlight and inflammables. Never connect the AC motor drive output terminals U/T1, V/T2 and W/T3 directly to the AC mains circuit power supply. The rated voltage of the AC motor drive must be 240V for 230V models, and 480V for 460V models.
Only qualified persons are allowed to install, wire and maintain the AC motor drives. Even if the 3-phase AC motor is stopped, a charge may still remain in the main circuit terminals of the AC motor drive with hazardous voltages. If the AC motor drive is stored in no charge condition for more than 3 months, the ambient temperature should not be higher than 30°C. Storage longer than one year is not recommended, it could result in the degradation of the electrolytic capacitors. Pay attention to the following when transporting and installing this package (including wooden crate, wood stave and carton box) 1.
If you need to sterilize, deworm the wooden crate or carton box, please do not use steamed smoke sterilization or you will damage the VFD. 2. Please use other ways to sterilize or deworm. 3. You may use high temperatures to sterilize or deworm. Leave the packaging materials in an environment of over 56°C for 30 minutes. 4. It is strictly forbidden to use steamed smoking sterilization. The warranty does not covered VFD damaged by steamed smoking sterilization. Connect the drive to a 3-phase three-wire or 3-phase four-wire Wye system to comply with UL standards. Since the leakage current of the motor drive is higher than 3.5 mA a.c.
or 10 mA d.c., the end users are advised to follow at least one of the procedures below to avoid electric shock: 1. Connect the motor drive to the ground by using a copper wire with a sectional area of 10 mm2 minimum or an aluminum wire with a sectional are of 16 mm2 minimum. 2. Install an electricity leakage breaker. NOTE
Table of Contents
Table of Contents CHAPTER 1 INTRODUCTION .................................................................................................
1-1 1-1 Nameplate Information................................................................................................1-2 1-2 Model Name...............................................................................................................1-3 1-3 Serial Number..............................................................................................................1-3 1-4 RFI Jumper..................................................................................................................1-4 CHAPTER 2 DIMENSION ........................................................................................................
2-1 Frame B……………………………………………………………..……………………………2-1 Frame C……………………………………………………………..……………………………2-2 Frame D…………………………………………………………..………………………………2-3 Frame E…………………………………………………………..………………………………2-4 Frame F…………………………………………………………..………………………………2-5 Digital Keypad…………..……………………………………………………………………….2-6 CHAPTER 3 INSTALLATION ................................................................................................... 3-1 CHAPTER 4 WIRING ...............................................................................................................
4-1 4-1 Wiring...........................................................................................................................4-3 4-2 System Wiring Diagram...............................................................................................4-6 CHAPTER 5 MAIN CIRCUIT TERMINALS ............................................................................
5-1 5-1 Main Circuit Diagram....................................................................................................5-4 5-2 Main Circuit Terminals..................................................................................................5-5 Frame B………..………………………………………………..……………………………5-6 Frame C………..………………………………………………..……………………………5-7 Frame D………...……………………………………………….……………………………5-8 Frame E…………...…..………………………………………….………………………..…5-9 Frame F………….…….……...………………………………….…………………………5-10 CHPATER 6 CONTROL TERMINALS .....................................................................................
6-1 CHAPTER 7 OPTIONAL ACCESSORIES ...............................................................................
7-1 7-1 All Brake Resistors and Brake Units Used in AC Motor Drives...................................7-2 7-2 Non-fuse Circuit Breaker............................................................................................7-4 7-3 Fuse Specification Chart ...........................................................................................7-5 7-4 AC/DC Reactor...........................................................................................................7-7 7-5 Zero Phase Reactor.................................................................................................7-19 7-6 EMC Filter.................................................................................................................7-22 7-7 EMC Shield Plate....................................................................................................7-26 7-8 Capacitive Filter.........................................................................................................7-29 7-9 Conduit Box…..........................................................................................................7-31 II
Table of Contents
7-10 Fan Kit.....................................................................................................................7-37 7-11 Keypad Panel Mounting ……..................................................................................7-38 7-12 DIN-Rail Mounting...................................................................................................7-39 CHAPTER 8 OPTION CARDS ..................................................................................................
8-1 8-1 Option Card Installation................................................................................................8-2 8-2 CMM-MOD01 MODBUS/TCP Option Card..................................................................8-9 8-3 CMM-PD01 PROFIBUS Option Card.........................................................................8-12 8-4 CMM-DN01 DeviceNet Option Card..........................................................................8-14 8-5 CMM-EIP01 MODBUS TCP/EtherNet IP Option Card...............................................8-17 8-6 CMM-COP01 CANopen Option Card.........................................................................8-20 8-7 EMM-BPS01 Back-up Power Supply Card................................................................8-22 CHAPTER 9 SPECIFICATION ..................................................................................................
9-1 9-1 230V Series………………………………......................................................................9-2 9-2 460V Series………………………………......................................................................9-4 9-3 Environment for Operation, Storage and Transportation……………………...............9-7 9-4 Derating of Ambient Temperature and Altitude……………………................................9-8 CHAPTER 10 DIGITAL KEYPAD ........................................................................................... 10-1 CHAPTER 11 SUMMARPY OF PARAMETERS SETTINGS .................................................. 11-1 CHAPTER 12 DESCRIPTION OF PARAMETER SETTINGS ..........................................
12-00-1 CHAPTER 13 WARNING CODES .......................................................................................... 13-1 CHAPTER 14 ERROR CODES .............................................................................................. 14-1 CHAPTER 15 CANOPEN OVERVIEW ................................................................................... 15-1 CHAPTER 16 PLC FUNCTION APPLICATIONS ...................................................................
16-1 CHAPTER 17 SAFE TORQUE OFF FUNCTION………………….....……..…………………….17-1 17-1 Basic Function Description..................................................................17-2 17-2 Safe Torque Off Terminal Function Description......................................................17-3 17-3 Wiring Diagram.......................................................................................................17-4 17-4 Failure Rate of the Drive Safety Function...............................................................17-5 17-5 Reset the Parameter Settings............................................................................17-5 17-6 Timing Diagram Description......................................................................17-6 17-7 Error Code and Troubleshooting Instructions…………………………………….…17-9 17-8 Test and Fault Confirmation…………………………………………………….……17-11 III Application Control Board: