sinee — 6.2Table of functional parameters

User Manual of EM730 Series Inverter 6.2 Table of functional parameters 71 Attribute Change attribute of the function code (permission and condition of change), as described below: ● Changeable in running: The current function code can be changed in any status. 〇 Non-changeable in running: The current function code can be changed except in the running status. × Read-only: The current function code cannot be changed in any status. Function code Function code name Parameter description Unit Defau lt setting Attri but e mailing address F00 Basic function parameter group F00.00 Reserved F00.01 Drive control mode of motor 1 0: v/f control (VVF) 1:

speed sensorless vector control (SVC) 0 〇 0x0001 F00.02 Options of command source 0: keyboard control (LOC/REM indicator: ON) 1: terminal control (LOC/REM indicator: OFF) 2: communication control (LOC/REM indicator: flicker) 0 〇 0x0002 F00.03 Options of terminal control mode 0: terminal RUN (running) and F/R (forward/reverse) 1: terminal RUN (forward) and F/R (reverse) 2: terminal RUN (forward), Xi (stop) and F/R (reverse) 3: terminal RUN (running), Xi (stop) and F/R (forward/reverse) 0 〇 0x0003 F00.04 Options of main frequency source A 0: digital frequency setting F00.07 1:AI1 2:AI2 3:reserved 4:reserved 5: high frequency pulse input (X5) 6:

main frequency communication setting (percentage) 7: main frequency communication setting (direct frequency) 8: digital potentiometer setting 8 〇 0x0004 F00.05 Options of auxiliary 0: digital frequency setting F00.07 1:AI1 0 〇 0x0005