4-2 Function Mode 4 Functions *1. The Inverter's rated current is "1000". *2. The second decimal place is ignored when the value is over 10000 (100.0 seconds). 4-78 Register No. Function name Parameter No.
R/W function Data Resolution 000Dh PID feedback value monitor d004 (HIGH) R 0 to 999900 0.01 000Eh d004 (LOW) R 000Fh Multi-function input monitor d005 R 0 to 63 0010h Multi-function output monitor d006 R 0 to 7 0011h Output frequency monitor (after conversion) d007 (HIGH) R 0 to 999900 0.01 0012h d007 (LOW) R 0013h Output voltage monitor d013 R 0 to 600 1 [V] 0014h Total RUN time d016 (HIGH) R 0 to 999999 1.[h] 0015h d016 (LOW) R 0016h Power ON time monitor d017 (HIGH) R 0 to 999999 1.[h] 0017h d017 (LOW) R 0018h Fault frequency monitor d080 R 0 to 65535 0019h Fault monitor 1 d081 R Indicates the cause of the trip. 001Ah Fault monitor 2 d082 R Indicates the cause of the trip.
001Bh Fault monitor 3 d083 R Indicates the cause of the trip. 001Ch to 0022h Not used 0023h Output frequency setting/ monitor F001 R/W 0/Starting frequency to 4000 0.1 [Hz] 0024h Acceleration time 1 F002 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0025h F002 (LOW) R/W 0026h 2nd acceleration time 1 F202 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0027h F202 (LOW) R/W 0028h Deceleration time 1 F003 (HIGH) R/W 0 to 300000 *2 0.01 [s] 0029h F003 (LOW) R/W