Appendix-1 Parameter List Extended Function Mode * 2nd/3rd control is displayed when "SET(08)/SET3(17)" is allocated to one of multi-function inputs from C001 to C008. Appendix App-4 Parameter No. Function name Monitor or data range Default setting Changes during operation Unit Set value Basic setting A001 Frequency reference selection 00: Digital Operator (FREQ adjuster) (Enabled when 3G3AX-OP01 is used.) 01: Terminal 02: Digital Operator (F001) 03: ModBus communication 04: Option 1 05: Option 2 06: Pulse train frequency 07: Not used 10: Operation function result 02 No A002 RUN command selection 01: Terminal 02: Digital Operator (F001) 03: ModBus communication 04: Option 1 05:
Option 2 02 No A003 Base frequency 30. to Maximum frequency [A004] 60. No Hz A203 * 2nd base frequency 30. to 2nd maximum frequency [A204] 60. A303 * 3rd base frequency 30. to 3rd maximum frequency [A304] 60. A004 Maximum frequency 30. to 400. 60. No Hz A204 * 2nd maximum frequency 30. to 400. 60. A304 * 3rd maximum frequency 30. to 400. 60.