HOME A.10 MOLEX CONNECTORS MOLEX CONNECTOR REPAIR 5. With all terminals installed, push the secondary lock into the socket housing to lock the wire terminals into the housing. TOOL NAME PART NUMBER MOLEX ELECTRICAL CONNECTOR TERMINAL REMOVER HD-48114 sm00040 Separating Pin and Socket Housings See Figure A-26 . Depress the latch while pulling the pin and socket housings apart. Mating Pin and Socket Housings 1. Orient the latch on the pin housing to the latch pocket on the socket housing so the rails on the outside of the pin housings lines up with the tunnels on the socket housing. 2. Press the housings together until the latch clicks. Removing Terminals 1.
Pull the secondary lock up, approximately 4.8 mm (3/16 in.), until it stops. a. Socket Housing: See Figure A-27 . Use a small screwdriver in the pry slot. The slot next to the external latch provides a pivot point. Figure A-26. Molex Connector: Latch b. Pin Housing: See Figure A-28 . Use needle nose pliers to engage the D-holes in the center of the sec- ondary lock. NOTE Do not remove the secondary lock from the connector housing. sm03332 2. See Figure A-29 . Insert MOLEX ELECTRICAL CON- NECTOR TERMINAL REMOVER (Part No. HD-48114) into the pin hole next to the terminal until the tool bottoms. a. Socket Housing: The pin holes are inside the ter- minal openings. b. Pin Housing:
The pin holes are outside the pins. 3. Pressing the terminal remover to the bottom of the pin hole, gently pull on the wire to remove wire terminal from its cavity. Installing Terminals 1. See Figure A-30 . From the wiring diagram, match the wire color to its numbered terminal cavity. Figure A-27. Secondary Lock Pry Slot (Socket Housing) NOTE Cavity numbers (1) are stamped on the housing at the ends of the cavity rows. The cavity number can be determined by counting the cavities up or down along the row from each stamped number. 2. Orient the terminal so that the tang (2) opposite the open crimp engages the slot (3) in the cavity. 3. Push the terminal into the cavity. 4.
Gently tug on wire to verify that the terminal is captured by the secondary lock. 2009 VRSC Service: Appendix A Connector Repair A-19