HOME A.12 PACKARD 280 METRI-PACK RELAY AND FUSE BLOCK CONNECTORS FUSE BLOCK REPAIR NOTE Removing Socket Terminals The wiring diagram indicates when one socket terminal is be crimped to two wire leads. 1. See Figure A-40 . To remove secondary locks, insert end of small flat blade screwdriver (1) under lip of locking wedge (2) and gently pry up secondary lock. sm00025 NOTE For best results, start with locking wedge on outboard side of secondary lock. 1 2 2. Looking into chamber at top of fuse block, note the tang next to each socket terminal. 3. Using a thin flat blade, like that on a hobby knife, gently push tang away from terminal, and then tug on wire to back terminal out.
Installing Socket Terminals 1. Match the wire lead color to the fuse block terminal cavity. NOTES • Refer to the main harness wiring diagram for wire lead color codes. 1. Pry up secondary lock 2. Lip of locking wedge • See Figure A-41 . The main fuse block terminal cavity is identified as alpha (1) and numeric (2) coordinates. Refer to the main harness wiring diagram for fuse block terminal cavity coordinates. Figure A-40. Fuse Block: Remove Secondary Locks 2. With the open side of the socket terminal facing the tang, push lead into chamber at the wire end of the fuse block. A click is heard when the terminal is properly engaged. sm00026 1 3.
Gently tug on the wire to verify that the terminal is locked in place and will not back out of the chamber. 1 A C E G 4. Install the secondary locks. With the locking wedges positioned above the tangs in each chamber, slide flat side of secondary lock into slot (between rows), and push down until it bottoms. 2 2 3 Crimping Terminals 4 Terminals are crimped twice; once over the wire core and a second time over the insulation/seal. B D F H A correctly crimped terminal may require different crimping dies found on separate crimpers. 1. Alpha 2. Numeric Figure A-41. Fuse Block: Coordinates (typical) 2009 VRSC Service: Appendix A Connector Repair A-25 J