HOME A.16 PACKARD ECM CONNECTOR PACKARD 100W CONNECTOR REPAIR General sm00037 A Packard 100W connector connects the electronic control module (ECM) to the main harness. NOTE 3 For vehicles with 73-pin connectors, see A.17 PACKARD MICRO-64 CONNECTORS and A.15 PACKARD METRI-PACK TERMINALS . Separating Socket Housing From ECM See Figure A-45 . While pressing the connector into the ECM, press the thumb lever (1) against the connector until the latch (2) pops out of the catch (3) on the ECM. 1 2 Mating Socket Housing To ECM Push the connector into the ECM until the latch is captured by the catch on the ECM. Removing Socket Terminal 1. See Figure A-46 .
Gently press latch (1) on each side of the clear plastic secondary lock (2) and remove. For best results, release one side at a time. 2. Carefully cut cable strap (3) to free strain relief collar (4) from conduit (5). 1. Thumb lever 2. Latch 3. Catch (ECM) 3. See Figure A-47 . Using a thin blade, gently pry at seam at back of socket housing to release three plastic pins (1) from slots in housing. Separate and spread halves of socket housing. Figure A-45. Packard 100W to ECM (Typical) 4. Push on wire lead to free terminal from chamber. Installing Socket Terminal 1. From inside socket housing, gently pull on wire to draw terminal into chamber. 2.
Exercising caution to avoid pinching wires, press halves of socket housing together until three plastic pins fully engage slots in housing. 3. Install new cable strap in groove of strain relief collar capturing cable conduit. 4. With the two ribs on the secondary lock on the same side as the external latch, install over terminals until latches lock in place. Crimping Terminals If necessary, crimp new terminals on wire leads. See A.15 PACKARD METRI-PACK TERMINALS . A-30 2009 VRSC Service: Appendix A Connector Repair