HOME Installing Terminal 1. Insert terminal into its respective numbered chamber on wire end of connector. No special orientation of the ter- minal is necessary. sm00047 2 3 NOTE See Figure A-50 . For wire location purposes, the corners of the socket housing are stamped (3) with the numbers 1, 6, 7 and 12, representing terminals 1-6 on one side, and 7-12 on the other. 1 6 1 1 2 3 4 5 6 2. Bottom the terminal in the chamber and then gently tug on the wire to verify that it is locked in place. 7 8 9 10 11 12 NOTE Once the terminal is removed it may not lock in place when first reinstalled. Until the lock engages, move the terminal back and forth slightly while wiggling the lead. 7 12 1.

Secondary lock 2. Pin hole 3. Stamped number 3. Since the terminal remover tool releases two terminals simultaneously, repeat step 2 on the adjacent terminal even if it was not pulled from the connector housing. Figure A-50. Packard Micro 64 Connector: Housing 4. With the center ear on the head of the secondary lockpin facing the mating end of the connector, push secondary 1. 2. 3. 4. Figure A-51. Packard Micro 64 Terminal Crimper (HD-45929) 5. Release locking bar to lock position of contact. When correctly positioned, the locking bar fits snugly in the space at the front of the core crimp tails and the closed side of the terminal rests on the outer nest of the crimp tool. 6.

Insert wires between crimp tails until ends make contact with locking bar.Verify that wire is positioned so that wide pair of crimp tails squeeze bare wire strands, while the narrow pair folds over the insulation material. 7. Squeeze handle of crimp tool until tightly closed (4). Tool automatically opens when the crimping sequence is com- plete. 8. Raise locking bar and barrel holder to remove contact. Inspecting Crimps Inspect the quality of the core and insulation crimps. Distortion should be minimal. 2009 VRSC Service: Appendix A Connector Repair A-33 lock in until head is flush with the connector housing.

sm00045 paring Wire Leads for Crimping lead removing 3.0 mm (1/8 in.) of insulation. mping Terminals Inspect new socket terminal for bent or deformed contact and crimp tails. Replace as necessary. See Figure A-52. Squeeze the handles of the PACKARD MICRO-64 TERMINAL CRIMPER (Part No. HD-45929) to cycle the tool to the fully open position (1). Raise locking bar and barrel holder by pushing up on bottom tab with index finger (2). With the crimp tails facing upward, insert terminal through locking bar into front hole in barrel holder (20-22 gauge See Figure A-52. Squeeze the h MICRO-64 TERMINAL CRIMPE andles of the PAC R (Part No. HD-