A+ Server 4020A-8R User's Manual 6-4 Drive Bay Installation SCSI Drives Eight SCSI drives may be housed in the SC743S1-R760 chassis. The SCSI drive IDs are preconfi gured as 0 through 7 in order from bottom to top (tower confi gura- tion) or from left to right (if rackmounted). Note: You must use standard 1" high, 80-pin SCA SCSI drives in the AS 4020A- 8R. Use extreme caution when working around the SCSI backplane. no ribbon cables touch the backplane or obstruct the airfl ow. ! Do not touch the backplane with any metal objects and make sure 1. Removing a hot-plug SCSI drive carrier The eight SCSI drive carriers are all easily accessible at the front of the chassis.
The SCSI drives are hot-swappable, meaning they can be removed and installed without powering down the system. To remove a carrier, fi rst push the release button located beside the drive LEDs. Swing the handle fully out and use it to pull the unit straight out from the chassis(see Figure 6-5). Note: Your operating system must have RAID support to enable the hot-plug ca- pability of the SCSI drives. 2. Mounting a SCSI drive in a drive carrier The SCSI drives are mounted in drive carriers to simplify their installation and removal from the chassis. These carriers also help promote proper airfl ow for the SCSI drive bays.
For this reason, even empty carriers without SCSI drives installed must remain in the chassis. To add a new SCSI drive, install a drive into the car- rier with the printed circuit board side toward the carrier so that the mounting holes align with those in the carrier. Secure the drive to the carrier with two screws on each side, as shown in Figure 6-6. 6-6