Supermicro A+ Server 4022G-6F — Supermicro A+ Server 4022G-6F User's Manual PDF Download

Chapter 5: Advanced Serverboard Setup BMC Heartbeat LED A BMC (Baseboard Management Control) Heartbeat LED is located at DP1 on the motherboard. When DP1 is on, the BMC Controller functions normally. See the tables at right for more information. Power LED DP3 is an Onboard Power LED. When this LED is lit, it means power is present on the serverboard. Be sure to turn off the system and unplug the power cord(s) before removing or installing components. SAS2008 Heartbeat LED The LEDS1 SAS2008 Heartbeat LED on the H8DG6/H8DG6-F serverboards shows SAS2 activity on the serverboard. See the table to the right for information on this LED.

UID LED (LE1) A rear UID LED Indicator, located at LE1, works in conjunction with the rear UID switch to provide easy identification for a unit that might be in need of service. Refer to Page 2-13 for further UID details. 5-25 BMC Heartbeat (DP1) LED Settings Color Status Definition Green Blinking BMC: Normal Off Off Not functioning normally Power LED (DP3) State System Status On Standby power present on motherboard Off No power connected SAS2008 Heartbeat LED (LEDS1) State System Status Blinking SAS Controller is Active Off SAS Connector Inactive