Lenze — 4.7 Control terminals

Single-axis controllers Control terminals 4 4.7 Digital outputs The controller features four freely configurable digital outputs.  Note! For stable digital output states, in particular during the starting phase of the controller, you must use an external 24V supply for the digital outputs.  Note! Digital inputs and digital outputs have separated reference potentials (GI and GO). If you interconnect inputs and outputs, the reference potentials are connected as well by an external bridge. ~ + - 24 V = F   GO X4 GND GO X4 24O In 24O DO2 DO1 DO2 DO1 DO3 DO3 DO4 DO4 Fig. 4.7-3 Wiring principle SSP94X4DO1  Wiring with a digital input, e.g.

a PLC  Digital control (relay, valve, ...) with an external 24-V supply X4 Terminal for the digital outputs In Digital input, e.g. of a control GND Earth reference potential F Fuse  4.7-8 EDS94SPP101 EN 3.1-04/2007 Electrical data 24O (external voltage source, optional) Rated voltage 24 V According to IEC 61131-2 Current consumption Max. 300 mA DO1 ... DO4 Switching level LOW HIGH According to IEC 61131-2 0 V ... +5 V +15 V ... +30 V Output current Max. 50 mA Load > 480 Ω at 24 V