Lenze — 4.2 General data and operating conditions

Single-axis controllers General data and operating conditions 4 4.2 The protective insulation of the 9400 Servo Drives controllers complies with EN 61800-5-1. The following illustration ƒ shows the arrangement of the terminal strips and the separate potential areas of the controller. ƒ serves to determine the decisive protective insulation between two terminals located in different separate potential areas. Bus Ext. DC Protective insulation acc. to EN 61800-5-1 (Definition of terms: see glossary) Functional insulation Basic insulation I/O Reinforced insulation Ext.

DC E94YCXX007 Example Which type of protective insulation is used between the bus terminal of the device module in slot MXI1 or MXI2 and the mains terminal X100? The separate potential area with the better protective insulation is decisive. ƒ The separate potential area of the device module bus terminal is ”functionally insulated”. ƒ The separate potential area of the mains terminal has a ”reinforced insulation”. Result: The insulation between the mains terminal X100 and the bus terminal is of the ”reinforced insulation” type.

 4.2-6 EDS94SPP101 EN 3.1-04/2007 X100 X107 X106 X105 X1 X2 M X3 X4 M X5 X6 M X7 M X8 X106 X107 Terminal strip Terminal Terminal strip Terminal X100 z L1, L2, L3 z +UG, -UG X1 CAN on board 9400 X2 z State bus X105 z U, V, W z 24 V (ext.) z Rb1, Rb2 X3 Analog input / output X106 Motor PTC X4 Digital output X107 Control of motor holding brake X5 Digital input X6 Diagnostics X7 Resolver X8 Encoder MXI1, MXI2 Extension module MMI Memory module MSI Safety module