Lenze — 4.3.2 Operation at rated mains voltage 230 V

4 4.3 4.3.2 Single-axis controllers Rated data (devices for 400/500V mains) Operation at rated mains voltage 230 V 4.3.2 Operation at rated mains voltage 230 V Device size 1 ... 6 Device size 7  4.3-4 EDS94SPP101 EN 3.1-04/2007 Basis of the data Mains Voltage ULN [V] Voltage range ULN [V] Frequency range f [Hz] 230 180 - 0 % ... 264 + 0 % 325 260 - 0 % ...

370 + 0 % Mains current at IaN Output power Motor power (typical) with external mains choke without external mains choke U, V, W 4-pole ASM Type ILN [A] ILN [A] SaN [kVA] PaN [kW] PaN [hp] E94ASxE0024 1.5 2.1 0.5 0.18 0.25 E94ASxE0034 2.5 3.5 0.9 0.37 0.5 E94ASxE0044 3.9 5.5 1.4 0.75 1 E94ASxE0074 7.0 9.9 2.5 1.5 2 E94ASxE0134 12.0 16.8 4.7 3 4 E94ASxE0174 15.0 21.0 5.9 4 5.5 E94ASxE0244 20.5 29.0 8.4 5.5 7.5 E94ASxE0324 - 29.0 11.5 7.5 10 E94ASxE0474 - 43.0 16.9 11 15 E94ASxE0594 - 54.0 21.2 15 20 Basis of the data Mains Voltage ULN [V] Voltage range ULN [V] Frequency range f [Hz] 3/PE AC 230 180 - 0 % ... 264 + 0 % 45 - 0 % ...

65 + 0 % Mains current at IaN Output power Motor power (typical) with external mains choke without external mains choke U, V, W 4-pole ASM Type ILN [A] ILN [A] SaN [kVA] PaN [kW] PaN [hp] E94ASxE0864 - 79.0 30.8 22 29 E94ASxE1044 - 95.0 37.3 30 40