sinee — 9.2 Function Parameter List

A90 series Inverter User Guide 54 F07.11 Current Limit Control 0: Disabled 1: Enabled Mode 1 2: Enabled Mode 2 2 〇 F07.12 Current Limit Level 20.0 - 180.0 (100.0= Inverter Rated Current) % 150.0 ● F07.13 Rapid Current Limit 0: Disabled 1: Enabled 0 〇 F07.14 Fault Retry Times 0 – 20, 0: Fault Retry Disabled 0 〇 F07.15 Digital Output Action at Fault Retry 0: Disabled 1: Enabled 0 〇 F07.16 Fault Retry Interval 0.01 - 30.00 s 0.50 ● F07.17 Recovery Time of Fault Retry Times 0.01 - 30.00 s 10.00 ● F07.18 Fault Retry setting E07 E03 E02 E06 E05 E04 **0 00000 〇 0: Permitted 1: Not Permitted F07.19 Stop mode 1 at Fault E21 E16 E15 E14 E13 E12 E08 E07 000 00000 〇 0: Coast to Stop 1:

Stop as per F04.19 F07.20 Stop mode 2 at Fault E28 E27 E25 E23 *0000 〇 0: Coast to Stop 1: Stop as per F04.19 F07.21 Offload Protection 0: Disabled 1: Enabled 0 ● F07.22 Offload Detection Level 0.0 - 100.0 % 20.0 ● F07.23 Offload Detection Time 0.0 - 60.0 s 1.0 ● F07.24 Offload Protection setting 0: Coast to Stop 1: Stop as per F04.19 2: Continue to run, the digital output terminal is valid 1 〇 F07.27 Automatic Voltage Regulation(AVR) 0: Disabled 1: Enabled 2:

Automatic 1 〇 F07.28 Stall fault detection time 0.0~6000.0 s 0.0 〇 F07.29 The intensity of stall control 0~100 % 100 〇 F07.30 Deceleration time of the continuious woking under instantaneous power failure 0.0~300.0 s 20.0 〇 F08 Preset Speed and Simple PLC F08.00 Preset Speed 1 0.00 - Maximum Frequency F00.16 Hz 0.00 ● F08.01 Preset Speed 2 0.00 - Maximum Frequency F00.16 Hz 5.00 ● F08.02 Preset Speed 3 0.00 - Maximum Frequency F00.16 Hz 10.00 ● F08.03 Preset Speed 4 0.00 - Maximum Frequency F00.16 Hz 15.00 ● F08.04 Preset Speed 5 0.00 - Maximum Frequency F00.16 Hz 20.00 ●