User Manual of A90 Series Inverter machine. The function code, length and CRC of the data are correct. Fig. 0-4 shows the data sending segment (t send ), sending end segment (t wait1 ), 75176-to-sending wait segment (t wait2 ), data return segment (t return ), and 75176-to-receiving wait segment (t wait3 ). t wait 3 t t send t wait 1 t wait 2 t return Fig. 0-4 Timing Parse Diagram of Complete Data Frame 12.4.4 Communication timeout reception of valid data frames by the slave station (inverter) to next reception of valid data The communication time interval △ t is defined as the period from the previous frames.

If △ t is greater than the set time (depending on the function code F10.03; this function is invalid if set to 0), it will be regarded communication timeout. Fig. 0-5 Schematic Diagram of Network Link Data 485 12.5 Examples 1) Forward running of inverter Send: 01 41 70 0000 01 E6 C5 Return: 01 41 70 0000 01 E6 C5 (normal) Return: 01 C1 04 70 53 (exception, assuming a slave fault) 296