AC100 HIGH-PERFORMANCE VC INVERTER MANUAL OVERVIEW 6 Protection function Bus overvoltage, mains under voltage, inverter over-current, module failure, inverter overload, motor overload, current detection zero drift failure, Hall failure, E2ROM failure, motor grounding failure, input phase failure, output phase failure, inverter overheating, communication failure, PG card failure, PG disconnection failure, motor parameter self-tuning failure; Special Functions VC mode 2 modes:
1st mode providing high-performance speed effect; 2ed mode providing lower and simple performance testing method; Auto-learning Asynchronous motors, synchronous motors static parameter learning, rotation parameter learning; Static self-learning induction motors all parameters; PG vector control encoder self-learning; Supporting multiple Incremental encoder (5V, 12V power supply, frequency dividing output), resolver, SinCos encoders, absolute encoders; encoders VF separation Frequency, voltage can be independently given and regulated, supporting multi-channel given way; function Terminals, Analog quantity Providing 4-way virtual X terminals, 4-way virtual Y terminals; supporting delay adjustment of terminal rising and falling; Extending 3-way X terminals by analog quantity; Providing more than two points analog quantity for analog calibration; Motor grounding Can detect whether the motor is shorted to ground and the electricity can be automatically detected; short circuit detection Servo control Supporting basic functions like synchronous and asynchronous servo control, pulse tracking, zero servo positioning servo index location, supporting quadrature pulse given; Telecommunication network supporting 485 / Modbus protocol, CANopen protocol, profibus-DP protocol; Modbus freedom protocol, CAN custom protocols, networking and linkage control between WEICHI inverters can be realized; Remote and monitoring function Supporting remote upgrading, remote monitoring, remote locking function, can be connected to WEICHI 3G module; Supporting virtual oscilloscope monitoring and debugging; Keyboard display LED display Single row 4 digital tube display Can monitor one state variable Two row 5 digital tube display Can monitor two state variables Parameter copy Function code information of frequency inverter can be uploaded and transferred to realize fast parameter copy.
State monitoring Output frequency, given frequency, output current, input voltage, output voltage, motor speed, PID feedback, PID given value, module temperature, input and output terminal status Environment Installation site Indoor, altitude ≤1000m, no corrosive air or direct sunshine Temperature, humidity -10 ~ +40℃ 20%—90%RH(no condensation) Vibration Under 20Hz≤0.5g Storage temperature -25—+65℃ Installation method Hanging type, cabinet type Protection level IP20 Cooling method Forced air cooling