omron — CommunicationToolResults

CommunicationToolResults CommunicationToolResults VRESULT 2600 Returns the total number of results that have been queued by all communication tools within a given sequence. This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 2600, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2600, index_id, frame_id) Type Integer Parameters ACE Reference Guide, 18317-000 Rev A Page 156 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Should always be set to -1.

instance id _ Not used ID 2600: the value used to reference this property. index id _ Not used frame id _ Not used