omron — Edge1Constraints

Edge1Constraints Edge1Constraints VPARAMETER 5221 Defines the detection constraints for the first edge of the selected pair. Constraints can be set for position and/or magnitude and are used to score edges.

Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5221, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5221, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5221, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5221, index_id, object_id) Type Long Range Parameters ACE Reference Guide, 18317-000 Rev A Page 174 Value Constraint Name Description 0 hsNone No constraint 1 hsPosition Position constraint 2 hsMagnitude Magnitude constraint 3 hsAllConstraints Magnitude and position constraints. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.

sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1.