EdgeMagnitudeThreshold EdgeMagnitudeThreshold VPARAMETER 5201 Magnitude threshold is used to find edges on the magnitude curve. In order to locate edges, a subpixel, peak-detection algorithm is applied on the region of every minimum or maximum of the curve that exceeds this threshold. Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5201, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5201, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5201, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5201, index_id, object_id) Type Range Minimum: 0 Maximum:
255 Parameters ACE Reference Guide, 18317-000 Rev A Page 212 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5201: the value used to reference this property. index id _ N/A object id _ N/A