omron — Found

Found Found VRESULT 1800 Specifies if an entity was found. If True, at least one entity (point, line or arc) was found in the current image. This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 1800, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1800, index_id, frame_id) Type Long Range Parameters ACE Reference Guide, 18317-000 Rev A Page 261 Value State Description 0 False No entity was found. 1 True An entity was found. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.

tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1800: the value used to reference this property. index id _ N/A frame id _ N/A