omron — InstanceClearQuality

InstanceClearQuality InstanceClearQuality VRESULT 1319 Measure of the unencumbered area surrounding the specified object instance. Clear quality ranges from 0 to 1, with 1 being the best quality. A value of 1 means that the instance is completely free of obstacles. This property is read-only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1319, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1319, index_id, frame_id) Type Double Remarks In MicroV+/V+, the frame_id parameter is required. Range Minimum: 0.0 Maximum: 1.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 299 sequence id _ Index of the vision sequence.