omron — InstanceTime

InstanceTime InstanceTime VRESULT 1322 Time, in milliseconds, needed to recognize and locate the selected object instance. This property is read- only. Syntax MicroV+ value = VRESULT (sequence_id, tool_id, instance_id, 1322, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1322, index_id, frame_id) Remarks The time needed to locate the first object instance is usually longer because it includes all low-level image preprocessing. In MicroV+/V+, the frame_id parameter is required. Type Double Range Greater than 0. Parameters ACE Reference Guide, 18317-000 Rev A Page 328 $ip IP address of the vision server. Applies to V+ syntax only.

Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result.