omron — MatchThreshold

MatchThreshold MatchThreshold VPARAMETER 5420 Sets the minimum match strength required for a pattern to be recognized as valid. A perfect match value is 1. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 5420, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5420, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5420, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5420, index_id, object_id) Remarks In MicroV+/V+, the frame_id parameter is required. Type Double Range Minimum: 0.0 (weak match) Maximum: 1.0 (strong match) Parameters ACE Reference Guide, 18317-000 Rev A Page 362 $ip IP address of the vision server.

Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5420: the value used to reference this property.