MaximumInstanceCountEnabled MaximumInstanceCountEnabled VPARAMETER 518 When True, limits the search to the number of instances set by the MaximumInstanceCount property Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 518, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 518, index_id, object_id) Type Long Range Parameters ACE Reference Guide, 18317-000 Rev A Page 370 Value Description 1 Search is limited to number of instances specified by MaximumInstanceCount. 0 Search is not limited to a set number of instances.
sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 518: the value used to reference this property. index id _ N/A object id _ N/A $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120.