omron — MeasurementPointsCount

MeasurementPointsCount MeasurementPointsCount VRESULT 2002 The number of points where the local sharpness is evaluated. When the Image Sharpness tool is executed, it scans the region of interest and identifies a number of candidate locations (equal to CandidatePointsCount) where the local standard deviation is the highest. The local sharpness is then evaluated at each of the candidate locations that has a local standard deviation above StandardDeviationThreshold. This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 2002, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 2002, index_id, frame_id) Type Long Range Minimum:

0 Maximum: CandidatePointsCount Parameters ACE Reference Guide, 18317-000 Rev A Page 374 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 2002: the value used to reference this property. index id _ N/A object id _ N/A