MinimumClearPercentageEnabled MinimumClearPercentageEnabled VPARAMETER 558 When set to True, the MinimumClearPercentage constraint is applied to the search process. Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 558, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 558, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 558, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 558, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 379 Value Description 1 The MinimumClearPercentage constraint is enabled and applied to the Search process. 0 The MinimumClearPercentage constraint is not enabled.
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 558: the value used to reference this property. index id _ N/A object id _ N/A