ModelDisambiguationEnabled ModelDisambiguationEnabled VPARAMETER 403 When set to True (default), the Locator applies disambiguation to discriminate between similar models and similar hypotheses of a single object. When set to False, the Locator does not apply disambiguation.
Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 403, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 403, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 388 Value Description 1 Locator applies disambiguation. 0 Locator does not apply disambiguation. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.
tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 403: the value used to reference this property.