omron — PairScore

PairScore PairScore VRESULT 1924 Score of the selected pair. The score of the pair is equal to the mean score of the two edges (Edge1Score and Edge2Score) that form the pair. This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 1924, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1924, index_id, frame_id) Type Double Range Minimum: 0.0 Maximum: 1.0 Parameters ACE Reference Guide, 18317-000 Rev A Page 429 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.

tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1924: the value used to reference this property. index id _ N/A frame id _ N/A