Sharpness Sharpness VRESULT 2000 Average sharpness computed in the region of interest. When the Image Sharpness tool is executed, it scans the region of interest and identifies a number of candidate locations (equal to CandidatePointsCount) where the local standard deviation is the highest. The local sharpness is then evaluated at each of the candidate locations that has a local standard deviation above StandardDeviationThreshold. The tool then computes the average of all the local sharpness values, which were computed at every measurement point, and returns it through the Sharpness property. This property is read-only.
Syntax MicroV+ value = VPARAMETER (sequence_id, tool_id, 2000, index_id, object_id) V+ value = VPARAMETER ($ip, sequence_id, tool_id, 2000, index_id, object_id) Type Double Range Minimum: 0 Maximum: 1000 Parameters ACE Reference Guide, 18317-000 Rev A Page 495 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 2000: the value used to reference this property. index id _ N/A object id _ N/A