ShowResultsGraphics ShowResultsGraphics VPARAMETER 150 When enabled, vision results are displayed in the image display control. When disabled, vision results are not displayed. Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 150, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 150, index_id, object_id) Type Boolean Range Parameters ACE Reference Guide, 18317-000 Rev A Page 497 Value Description 1 Enabled: Vision results are displayed in the image display control. 0 Disabled: Vision results are not displayed.
$ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 150: the value used to reference this property.