omron — ThresholdWhite

ThresholdWhite ThresholdWhite VPARAMETER 5321 Brightest greylevel value to consider when building the histogram. Greylevel values above ThresholdWhite are ignored during the histogram creation process. When a threshold is used and the tool is also configured to remove a percentage of pixels at the bright tail of the histogram (see the TailWhite property), the tail removal process begins to scan the histogram at the bin corresponding to ThresholdWhite instead of starting at bin 255.

Syntax MicroV+ VPARAMETER (sequence_id, tool_id, 5321, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5321, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5321, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5321, index_id, object_id) Type Long Range Minimum: 0 Maximum: 255 Parameters ACE Reference Guide, 18317-000 Rev A Page 511 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5321:

the value used to reference this property. index id _ N/A object id _ N/A