omron — AutomaticCandidateCountEnabled

AutomaticCandidateCountEnabled AutomaticCandidateCountEnabled VPARAMETER 5301 When set to True, the number of candidate measurement points is automatically determined according to the dimension of the tool region of interest. When set to False, the number of candidate measurement points is set manually through the CandidatePointsCount property.

Syntax Micro V+ VPARAMETER (sequence_id, tool_id, 5301, index_id, object_id) = value value = VPARAMETER (sequence_id, tool_id, 5301, index_id, object_id) V+ VPARAMETER (sequence_id, tool_id, 5301, index_id, object_id) $ip = value value = VPARAMETER ($ip, sequence_id, tool_id, 5301, index_id, object_id) Type Long Range Parameters ACE Reference Guide, 18317-000 Rev A Page 84 Value Description 1 The number of candidate measurement points is set automatically. 0 The number of candidate measurement points is set manually. $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence.

The first sequence is 1. tool id _ Index of the tool in the vision sequence. The first tool is 1. ID 5301: the value used to reference this property.