omron — AverageContrast

AverageContrast AverageContrast VRESULT 1801 Average contrast, expressed in greylevel values, between light and dark pixels on either side of the found entity (point, line, or arc). This property is read-only. Syntax Micro V+ value = VRESULT (sequence_id, tool_id, instance_id, 1801, index_id, frame_id) V+ value = VRESULT ($ip, sequence_id, tool_id, instance_id, 1801, index_id, frame_id) Type Double Range Minimum: Greater than 0. Maximum: 255 Parameters ACE Reference Guide, 18317-000 Rev A Page 86 $ip IP address of the vision server. Applies to V+ syntax only. Uses standard IP address format, for example: 192.168.1.120. sequence id _ Index of the vision sequence. The first sequence is 1.

tool id _ Index of the tool in the vision sequence. The first tool is 1. instance id _ Index of the instance for which you want the result. ID 1801: the value used to reference this property. index id _ N/A frame id _ Frame that contains the entity for which you want the result.