Delta Electronics AH — MC_Halt

AH Motion Controller – Motion Control Instructions Manual Motion diagram: Velocity 300 Time _3 - When M3( Execute ) of MC_Halt changes to True, it triggers M23( CommandAboted ) of MC_MoveVelocity at the same time and the motion controller starts to decelerate the axis to a stop. The Axis state is moved to the “DiscreteMotion”. - When the axis reaches zero velocity, M30( Done ) will change to True. The axis state transferred to “Standstill”. - If MC_MoveVelocity is executed again while MC_Halt is decelerating the axis and M3( Execute ) is True, the execution of MC_Halt will be aborted M33( CommandAboted ) = True and M2( Execute ) changes to True. MC_MoveVelocity will accelerate again.

 Supported Products − AH Motion Controller CPU: AHxxEMC-5A − AH series motion control modules: AHxxEMC-5A 3-42 MC MoveVelocity _ M2(Execute) M20(InVelocity) M21(Busy) M22(Active) M23(CommandAborted) M24(Error) MC Halt _ M3(Execute) M30(done) M31(Busy) M32(Active) M33(CommandAborted) M34(Error)