Delta Electronics AH — MC_Halt

Chapter 3 Motion Control Instructions - Information regarding error codes and indicators are attached as Appendices for a quick reference. The detailed troubleshooting procedures are explained in AH Motion Controller – Operation Manual .  Programming Example The example below describes the behavior of MC_Halt in combination with MC_MoveVelocity. The MC_Halt stops MC_MoveVelocity if there is no another instruction executed before the axis enters “Standstill” state. If MC_MoveVelocity executes again during the deceleration, it will abort MC_Halt immediately and accelerate again without entering “Standstill” state. This re-execution behavior is allowed for MC_Halt but not allowed in MC_Stop.

3_ 3-41