Chapter 3 Motion Control Instructions Function The instruction performs speed control with specified target velocity ( Velocity ), acceleration rate ( Acceleration ), deceleration rate ( Deceleration ) and Jerk value ( Jerk ) when execute changes to True. - You can execute another motion instruction to abort the ongoing motion of MC_VelocityControl. - The output InVelocity is reset when the instruction is aborted by another instruction.
- During the execution of the instruction MC_VelocityControl in CSV control mode, if users execute MC_Stop, MC_Halt or the axis is in the state of Errorstop, when the target velocity (60FF hex) decelerates to 0, the mode will be switched to CSP control mode. Refer to its servo manual for more details on the actual servo behavior. - The motion path of different velocity parameters is described as below. Acceleration / Deceleration =0 When the instruction is executed with Acceleration or Deceleration set to 0, no accelerating or decelerating will be performed on the axis before it reachs the specified target velocity.
Velocity 3_ Target Velocity Acceleration / Deceleration / Jerk ≠ 0 0 Position Setting up Acceleration/Deceleration/Jerk value allows you to control the motion path to ramp up (accelerate) or ramp down (decelerate) smoothly. The effects on a motion path with Jerk specified are as below. Velocity Target Velocity 0 Position - The behavior of the MC_VelocityControl instruction followed by MC_Stop instruction is described as below. 3-91