Chapter 3 Motion Control Instructions MC_TorqueControl 3_ The actual movement will be limited by other input conditions , depending on the mechanical application conditions. Before using MC_TorqueControl instruction, it is required to confirm if the below object data is supported, and use ECAT Builder in ISPSoft to set the below data in the settings of PDO communications. Target torque (6071 hex) Modes of operation (6060 hex) Torque actual value (6077 hex) Modes of operation display (6061 hex) Torque ramp (6087 hex) Maximum velocity (6080 hex) If one of the above required object data is not set, an error will occur to indicate the problem of missing process data object setting.
1. The instruction is also applicable for force control when there is no external load. 2. When one MC_TorqueControl instruction is executed but not finished yet, it is invalid to re-execute the instruction. Inputs 3-95 FB/FC Description FB MC TorqueControl controls the torque by using the Torque Control Mode of the applied servo drive. _ Name Function Data type Setting value (Default value) Timing for updating Execute Executes the instruction when BOOL True/False - Execute changes to True. (False)