Delta Electronics AH — MC_TorqueControl

AH Motion Controller – Motion Control Instructions Manual _3 *Note: 1. When the slave is Delta A2-E servo drive, when ContinuousUpdate is ON and the value of Torque is updated, this will cause the velocity to shift. 2. Take A2-E as an example, the torque ramp (6087 hex) will be defined as below: Torque (Unit: 0.1%) Torque (Target Torque Value) 3. Refer to Section 2.4 Data Type Unit (DUT): ENUM for explanation on using enumerations. Time (Unit: ms) 3-96 Name Function Data type Setting value (Default value) Timing for updating Continuous Update Continuously updates Torque when Continuousupdate is True BOOL True/False (False) When Active shifts to True and it will update continuously.

Torque The specified target torque (Unit: refer to 6071 hex in the object dictionary) LREAL Refer to 6071 hex in the object dictionary (0) When Execute shifts to True and Busy is False. TorqueRamp The specified maximum time derivative of the desired torque value. (Unit: refer to 6087 hex in the object dictionary) LREAL Refer to 6087 hex in the object dictionary (0) When Execute shifts to True and Busy is False. Velocity The maximum velocity. (Unit: refer to 6080 hex in the object dictionary) LREAL Refer to 6080 hex in the object dictionary (0) When Execute shifts to True and Busy is False.

Acceleration Reserved - - - Deceleration Reserved - - - Jerk Reserved - - - Direction*3 Reserved - - - BufferMode Specifies the buffering behavior of the instruction. eMC BUFF _ ER MODE*3 _ 0: mcAborting 1: mcBuffered (0) When Execute shifts to True and Busy is False.