Delta Electronics AH — MC_SetOverride

Chapter 3 Motion Control Instructions  Outputs Update Timing  Timing Diagram Enable 3_ Enabled Busy Error Error ID  In-Outs *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Function - The MC_SetOverride instruction changes the target velocity (and acceleration/deceleration/jerk, if applicable) of the motion axis with its specified override factors. - The new target velocity can be obtained by the equation as below. The new target velocity = Current target velocity Ч The specified override factor - The override value will command the axis to accelerate or decelerate to the target velocity.

- By setting the velocity override value as 0, you can pause the axis motion while keeping the operation status. Specifying the velocity override factor as 0 will change the target velocity to 0 and decelerate the axis to a velocity of 0 while keeping the axis operation status. - Whenever Enable is True, the override factors will be updated continuously. - The override factors stay the same when Enable shifts to False or an error occurs. - If another MC_SetOverride is executed during the current execution of MC_SetOverride, the execution of the 3-117 Name Timing for shifting to True Timing for shifting to False Enabled  When Enable shifts to True and the axis is ready to be operated.

 After one period when Enable shifts to False.  When Error shifts to True. Busy  When Enable shifts to True and the instruction is executed  When Enable shifts to False.  When Error shifts to True. Error/ErrorID  When an error occurs in the execution conditions or input values for the instruction.(Error code is recorded)  When Enable shifts from True to False. (Error code is cleared) Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Enable shifts to True and Busy is False.