Chapter 3 Motion Control Instructions MC_TouchProbe Before using MC_TouchProbe instruction, it is required to confirm if the below object data is supported, and use ECAT Builder in ISPSoft to set the below data in the settings of PDO communications. 3_ Touch probe funciton (60B8 hex) Touch probe status (60B9 hex) Touch probe pos1 pos value (60BA hex) Touch probe pos1 neg value (60BB hex) Touch probe pos2 pos value (60BC hex) Touch probe pos2 neg valu (60BD hex) If one of the above required object data is not set, an error will occur to indicate the problem of missing process data object setting.
Inputs 3-143 FB/FC Description FB MC TouchProbe captures and records an axis position when a trigger event occurs. _ Name Function Data type Setting value (Default value) Timing for updating TriggerSignal Specifies the trigger signal in controller mode*1 BOOL True/False Continuously updates value when Busy isTrue (False) Execute Executes the instruction and starts axis position recording when Execute changes to True. BOOL True/False (False) - WindowOnly Specifies if the window mask will be applied or not. The window mask is defined by FirstPosition and LastPosition BOOL True/False (False) When Execute shifts to True and Busy is False.
FirstPosition Defines the start position (positive direction) of the window mask to capture the trigger event (user unit*2) LREAL Negative number, positive number, or 0 (0) When Execute shifts to True and Busy is False.