Delta Electronics AH — MC_Reset

AH Motion Controller – Motion Control Instructions Manual  Timing Diagram  In-Outs _3 *Note : Kn refers to the maximum supported axes of different models. For example, AH20EMC-5A supports K1~K32.  Function - MC_Reset instruction starts the error reset process for the specified axis in Axis when Execute shifts to True. It resets axis-related errors and drive errors. - The instruction can be executed for any axis type. - Only the axes with errors are applicable for the error reset process. - If drive errors occur on an axis, the drive errors will be reset prior to the error reset process on the axis-related errors.

The reset process for drive errors will continue until either the drive error is reset or the Drive Error Reset Monitoring Time in the axis parameters is reached. - Errors that occur while error reset process is executing are not cleared. Only errors that existed while Execute shifts to True are cleared.  Troubleshooting - If an error occurs during the execution of the instruction or when the axis is in the state of “Errorstop”, Error will change to True and the axis will stop moving. You can refer to ErrorID (Error Code) to address the problem. - Information regarding error codes and indicators are attached as Appendices for a quick reference.

The detailed troubleshooting procedures are explained in AH Motion Controller – Operation Manual .  Supported Products - AH Motion Controller CPU: AHxxEMC-5A - AH series motion control modules: AHxxEMC-5A 3-142 Name Function Data type Setting value Timing for updating (Default value) Axis Motion axis number WORD K1~Kn* (0) When Execute is rising edge triggered and Busy is False