Chapter 3 Motion Control Instructions 3_ 3-153 Name Function Data type Setting value (Default value) Timing for updating CamTable Specifies a Cam table WORD 1~32 (0) When Execute shifts to True and Busy is False. Periodic Specifies a periodical execution or a one-time operation. True: Periodic; False: Non-periodic. BOOL True/False (False) When Execute shifts to True and Busy is False. MasterAbsolute Specifies the positioning mode of the master axis. True: Absolute mode False: Relative mode BOOL True/False (False) When Execute shifts to True and Busy is False. SlaveAbsolute Specifies the positioning mode of the slave axis. True: Absolute mode False:
Relative mode BOOL True/False (False) When Execute shifts to True and Busy is False. MasterOffset Shifts the position of LREAL positive number, negative When Execute the master axis by the number or 0 shifts to True and specified offset value. (0) Busy is False. SlaveOffset*2 Shifts the displacement of the slave axis by the specified offset value. LREAL positive number, negative number or 0 (0) When Execute shifts to True and Busy is False. MasterScaling Scales the master axis up and down with the specified factor. LREAL positive number (0) When Execute shifts to True and Busy is False. SlaveScaling Scales the slave axis up and down with the specified factor.
LREAL positive number (0) When Execute shifts to True and Busy is False. MasterStartDistance Reserved - - - MasterSyncPosition Specifies the relative position of the master axis when it starts to engage LREAL positive number, negative number or 0 (0) When Execute shifts to True and Busy is False. ActivationPosition Specifies the master position when it starts to engage and from LREAL positive number, negative When Execute number or 0 shifts to True and (0) Busy is False.