Delta Electronics AH — MC_CamIn

AH Motion Controller – Motion Control Instructions Manual _3 3-154 Name Function Data type Setting value (Default value) Timing for updating there the slave will start to engage. ActivationMode Specifies the mode of engement 0: Relative 1: Absolute MC ACTIVATION _ MODE*1 _ 0: Relative 1: Absolute (0) When Execute shifts to True and Busy is False. StartMode Specifies the engagement behavior of the slave axis eMC START MO _ _ DE*1 0: mcJump 1: mcRampIn Shortest _ 2: mcRampIn Positive _ 3: RampIn Negative _ (0) When Execute shifts to True and Busy is False. Velocity The maximum velocity for the engaging behavior specified by StartMode. (Unit:

user unit/s) * LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Acceleration The maximum acceleration rate for the engaging behavior specified by StartMode. (Unit: user unit/s) * LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Deceleration The maximum deceleration rate for the engaging behavior specified by StartMode. (Unit: user unit/s2) *2 LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False. Jerk The maximum jerk value for the engaging behavior specified by StartMode.. (Unit: user unit/s3) *2 LREAL Positive number or 0 (0) When Execute shifts to True and Busy is False.

MasterValueSource Specifies the reference position of the master axis. eMC SOURCE*1 _ 0: mcCommandedValue 2: mcActualValue (0) When Execute shifts to True and Busy is False. BufferMode Specifies the buffering behavior of the instruction. eMC BUFFER M _ _ ODE*1 0: mcAborting 1: mcBuffered (0) When Execute shifts to True.